5.8.2 PEP Virtual Port Attributes
5.8.2.1 Bridge Port
Description The bridge port for the PEP Virtual Port entry.
CLI Attribute Name bridge-port
SNMP Object ID ieee8021BridgeBasePort (1.3.111.2.802.1.1.2.1.1.4.1.2)
Value s1
Access N/A
Default N/A
Dependencies The Bridge Port specified in the command must be an internal port (PEP)
that belongs to the corresponding C-component.
5.8.2.2 PEP S-VID
Description The 12-bit S-VID that is associated with the PEP.
CLI Attribute Name s-vid
SNMP Object ID ieee8021PbEdgePortSVid (1.3.111.2.802.1.1.5.1.3.1.1)
Value 1..4094
Access N/A
Default N/A
Dependencies The VID must be defined in the VLAN Table for an S-component (See
Section 5.6).
5.8.2.3 PEP C-PVID
Description The 12-bit C-VID that will be used for untagged frames received at the
PEP
CLI Attribute Name cpvid
SNMP Object ID ieee8021PbEdgePortPVID (1.3.111.2.802.1.1.5.1.3.1.2)
Value 1..4094
Access RC
Default N/A
Dependencies The VID must be defined in the VLAN Table for the ports C-component
(See Section 5.6).