Page 21
If needed, change the ODU polarity position to match the orientation
of the remote pair ODU by removing the Quick Release Plate,
changing its orientation, and reattaching. For ease of reference, the
markings “V(vertical) andH (horizontal) are engraved on the
back side of the ODU.
Examine the position scales of both the Azimuth Adjustment Lock Bolts () and the
Elevation Adjustment Lock Bolts (), found on the Front Mounting Bracket, and
ensure that they are positioned at 0 degrees (in the middle of the scale).
Position the Quick Release Hooks () onto the top Elevation Adjustment Lock Bolt
() and carefully set the ODU in place on the Front Mounting Bracket.
Hint:
Mount the ODU by attaching the Interior Quick Release Hook (A) in place
before attaching the Exterior Hook (B). The Interior Hook is the one located
farthest from the tightening nut, as shown below.
A. Interior Quick Release Hook B. Exterior Quick Release Hook C. Elevation Position Slot
Finger-tighten the Azimuth Adjustment Lock Bolts () and the Elevation
Adjustment Lock Bolts ().
Stretch the Elevation Screw Tension Band () slightly and connect it to its mating
Tension Pin, located on the Quick Release Plate.
2.3.4 Ground Connection
The location of Grounding Outlet on the ODU is shown in Figure 2-2.
Connect one end of the Grounding Cable to the Ground Outlet on the left side of the
ODU using the Grounding Cable Lug. Tighten the lug securely in place.