The software version is followed by the creation date and time of the version. The first digit
of the version number represents the major version number, the second digit represents
the minor version number, the third digit represents the SVN revision, and the fourth digit
represents the version build number.
6.3.1.2 Copy a Software Version to the System
Copy a specified software version to the FibeAir 70 system using the Copy command:
copy sw <from-url>
The command downloads the software version image from the specified URL and copies it
to the Standby (not running) flash bank.
6.3.1.3 Activating a Software Version
Run a specified software version on the FibeAir 70 system using the Run command:
run sw {immediate | next-rst}
{<accept-timeout-sec> | no-timeout}
Upon execution, the command causes the System to be reset and then wake up with the
software version image that is stored on the Standby flash bank.
If immediate is specified as the first parameter on the command line, then a
Reset is performed immediately. This is the default value.
If next-rst is specified as the first parameter on the command line, then the next
System Reset that occurs (for whatever reason) will cause the System to wake up
with the software version stored in the Standby flash bank.
If <accept-timeout-sec> is specified as the second parameter on the command
line, then this duration in seconds is used as the safety timeout period in order to
manually enter the command accept sw. If no-timeout is specified as the
second parameter on the command line, then the command accept sw is not
expected and the Standby software version automatically becomes the Active
software version.
6.3.1.4 Accepting the Software Image
Running a new software version can be controlled using the Accept command:
accept sw
If the System wakes up with a software version stored in the Standby flash bank, then this
command turns the Standby (not running) version into the Active (running) version.